A bag filter is a pressure vessel that holds one or more filter bags. Liquid enters the housing, passes through the bag, and leaves the captured solids inside. It is used where a project needs fine particle capture at a controlled pressure drop, quick bag change-out and a compact footprint — typically as a guard before membranes, heat exchangers, spray nozzles or a distribution network. The housing is simple, but most failures come from a bag that is not seated, an O-ring that is the wrong material, a micron rating selected without checking the feed, or a multi-bag header that does not distribute flow evenly.
The reference range is 1, 5, 10, 25, 50 and 100 μm, with single-bag and multi-bag housings in carbon steel with internal lining, SS304/316L or PP. A size 2 bag has about 0.5 m² of media area and about 33 L of volume; a 25 μm bag in clean water is referenced at roughly 20–40 m³/h per bag. Use a safety factor of 1.2–1.5 on the design flow, and split a system into two housings when the count exceeds about 12 bags. These are reference values; the final selection depends on fluid, viscosity, solids load and the allowed pressure drop.
Form and construction
1. What housing shapes and inlet/outlet arrangements are available?
The standard bag filter housing is a vertical cylindrical shell with a hinged or bolted top cover, a bag support basket inside, and inlet and outlet nozzles on the side or bottom. Three common arrangements are side inlet with bottom outlet, side inlet with side outlet, and top inlet with bottom outlet. The side-in/bottom-out form is the most common for water because the inlet fills the housing above the bag and the outlet drains at the low point. The side-in/side-out form is used when the piping layout requires both connections at the same level. Top-in/bottom-out is used where the bag is loaded from the top and the outlet must be at the lowest point.
Single-bag housings are compact and easy to change. Multi-bag housings use a common shell with several bags and a header that distributes flow across the bag plate. The header design matters: if the flow favors the first bag, that bag clogs early while the others remain clean, and the pressure drop rises before the total dirt load is reached. A good multi-bag housing has a flow distributor, equal pressure at each bag and enough clearance above the bag plate for loading.
Housings can be skid-mounted with a pump, differential-pressure gauge and drain pan. For large flows, two smaller housings in parallel are often better than one very large housing because they allow one side to be serviced while the other stays online.
2. Single-bag or multi-bag — how many bags do I need?
Start with the design flow and the reference flow per bag at the selected micron rating. A 25 μm bag in clean water may pass 20–40 m³/h, but the same bag with a high solids load or a viscous fluid will be much lower. Apply a safety factor of 1.2–1.5, then round up to the next standard housing. If the calculation gives more than about 12 bags, split the duty into two housings rather than building one very large unit; this improves change-out access, limits the weight of a single housing and gives partial duty during maintenance.
Do not size only by the nominal flow printed on the bag. The bag is a depth filter, and its capacity depends on the particle size distribution, the allowable pressure drop and the change-out interval. A bag that is correctly sized for the flow but overloaded with solids will go into bypass or collapse before the scheduled change. Ask for the solids loading in mg/L and the target change-out interval, not only the flow.
For a batch process, size for the maximum batch flow, not the average. For a continuous process, size for the peak flow plus the safety factor. If the flow can be zero for long periods, provide a bypass or a recirculation line so that the housing does not sit stagnant.
3. What bag sizes and surface areas are available?
Size 1 and size 2 bags are the common small and medium sizes. A size 2 bag has about 0.5 m² of media area and about 33 L of volume. Larger sizes increase the area and the dirt-holding capacity without increasing the housing diameter too much. The bag collar and the housing neck must match; a bag that is nominally the right micron but the wrong collar will not seal.
The bag area determines the face velocity and the pressure drop. A larger bag in the same housing gives a lower face velocity and a longer run, but it also costs more and may require a different basket. The bag length must fit the basket and leave room for the bottom seal. If the bag is too long, it can fold or tear; if it is too short, it can bypass at the collar.
For multi-bag units, use the same bag size across the housing so that the pressure drop is balanced. Mixing bag sizes in one housing is possible only with a dedicated bag plate, and it complicates the spare-parts list. Standardise on one or two bag sizes across the site where practical.
4. Which housing material and seal should I choose?
Carbon steel with an internal lining is the economic choice for neutral water and many industrial duties. SS304 is used for potable water, food and moderate chloride; SS316L for higher chloride, purified water or aggressive cleaning chemicals. PP is used for acids, alkalis and chloride where stainless is not suitable, but check the temperature and pressure limits. The housing material must match the wetted fluid, not only the water name.
Seals are available in NBR, EPDM, FKM and silicone. NBR is good for water and many oils but not for strong oxidizers. EPDM is good for water, steam and many chemicals but not for mineral oils. FKM is good for high temperature and many chemicals but not for low-temperature water or some amines. Silicone is good for high temperature but has limited chemical resistance. The seal must be compatible with the cleaning and sanitising chemicals, not only the process fluid.
The bag collar gasket and the cover O-ring are separate seals. A cover O-ring that is correct for water may still fail in a CIP chemical. State the cleaning regime in the RFQ so that the seal material is selected for the whole cycle.
5. How do I select the micron rating?
Select the finest rating that meets the downstream requirement without causing an excessive pressure drop or a short bag life. If the bag protects a membrane, the rating should be consistent with the membrane manufacturer’s prefiltration requirement, often 5–25 μm depending on the membrane and the feed. If the bag protects a spray nozzle, use the nozzle’s recommended maximum particle size. If the bag is for general polishing, 25–50 μm is common, but the feed quality still decides.
Do not assume that a finer bag is always better. A 1 μm bag has a much lower dirt-holding capacity and a higher pressure drop than a 25 μm bag. In a stream with a high solids load, a 1 μm bag may blind in hours. A staged arrangement — a coarser bag upstream and a finer bag downstream — can give a longer combined run than a single very fine bag.
Check the particle size distribution, not only the nominal micron. A bag rated at 25 μm does not remove every particle above 25 μm with absolute certainty; it is a nominal rating with a defined efficiency. If the project needs absolute filtration, use a cartridge or a different technology, not a nominal bag.
6. How do I size the flow and the safety factor?
Use the design flow, the fluid viscosity, the solids loading, the allowable pressure drop and the target change-out interval. The reference flow for a 25 μm bag in clean water is about 20–40 m³/h, but this falls as viscosity rises or as the bag loads. Apply a safety factor of 1.2–1.5, and check the resulting face velocity against the bag supplier’s limit.
For viscous fluids, the pressure drop is dominated by viscosity, not only by the micron rating. A bag that works for water may be unacceptable for a syrup or a coating solution. Ask for the viscosity at the operating temperature and use the supplier’s viscosity correction. For high-solids streams, size for the dirt load and the change-out interval, not only the flow.
If the flow is variable, size for the maximum continuous flow and provide a second housing for peak or standby duty. A single housing that is oversized for normal flow may run at a very low face velocity and give poor dirt holding; a single housing that is undersized will bypass or collapse the bag.
Installation and commissioning
7. What installation height and clearance are needed?
Leave enough height above the cover to open it fully and remove the bag without bending the basket. For a top-loading housing, the cover swing and the bag length determine the clearance; a cover that opens only 45° may still require the bag to be pulled at an angle. Leave space around the housing for the differential-pressure gauge, the drain valve and a drip tray.
The housing should be mounted on a stable base or skid, with the outlet at the low point. If the housing is suspended, use a support that does not load the piping. The inlet and outlet flanges should align without forcing the pipe; a stressed flange can leak or crack. For PP and lined housings, support the shell along its length, not only at the base.
Provide a drain pan or a floor drain under the cover. Bag change-out always leaves some liquid in the housing, and a clean change-out area is part of the hygiene design. If the fluid is hazardous, provide a closed drain and a procedure for flushing before opening.
8. How is the bag installed correctly?
Open the cover, remove the old bag, clean the basket and the seal surface, and inspect the bag plate for cracks or product buildup. Insert the new bag with the collar seated in the groove, then fit the O-ring or the collar seal without twisting. The bag must hang freely inside the basket; a twisted or folded bag will restrict flow and may tear. Check that the bag collar is fully engaged before closing the cover.
Tighten the cover bolts evenly in a cross pattern. A single bolt tightened first can distort the cover and pinch the O-ring. Use the specified torque; over-tightening can damage the seal or the threads, and under-tightening will leak. For swing-bolt covers, check that all bolts are engaged and the cover is fully seated.
After closing, open the inlet slowly and vent the housing. Check for leaks at the cover and the drain. Record the bag rating, the installation date and the differential pressure at start-up. A bag that is installed with the collar folded will bypass unfiltered liquid even though the housing looks closed.
9. How is the housing commissioned and leak-tested?
Before filling, confirm that the housing is clean, the basket is intact, the drain is closed and the vent is open. Fill slowly with the process fluid or with water, vent the air, and check the cover and flange connections. Close the vent when liquid appears, then raise the pressure to the normal operating value and inspect for leaks. Record the clean-bag differential pressure; this is the baseline for bag change-out.
For potable or food duty, clean and sanitise the housing according to the project procedure before the first bag is installed. Use a sanitiser compatible with the housing material and the seal. Rinse thoroughly and test the residual. If the housing feeds a membrane, confirm that no sanitiser or fibres remain before starting the membrane.
Check the differential-pressure gauge and the vent. A gauge that reads zero at start-up may be isolated or blocked. A vent that is left open will prevent proper filling and may cause the bag to collapse. After commissioning, mark the normal valve positions and record the start-up pressure drop.
Operating problems
10. Why does the bag collapse or bypass?
A bag collapses when the pressure drop across it exceeds the bag’s strength or when the bag is not supported by the basket. Causes include a bag that is too long for the basket, a basket that is missing or damaged, a bag that is installed with the collar folded, or a flow that is far above the design. A collapsed bag can tear and pass solids downstream; a bypassed bag passes unfiltered liquid at the collar.
Check the basket, the bag length and the collar seating. Confirm the flow and the differential pressure. If the bag is correct but the pressure drop is high, the feed may be dirtier than expected or the micron rating may be too fine. Do not solve a collapsed bag by increasing the pump pressure; that makes the failure worse. Replace the bag and investigate the cause before restarting.
11. Why is the pressure drop high too early?
Early high pressure drop usually means the bag is overloaded, the micron rating is too fine, the fluid is more viscous than assumed, or the flow is above the design. It can also mean the bag is blinded by a contaminant that was not in the original analysis, such as oil, fibres or a polymer. Check the feed quality, the flow and the bag rating. If the feed has changed, a coarser prefilter or a staged arrangement may be needed.
Do not judge the bag only by the calendar. Change it when the differential pressure reaches the approved limit or when the downstream quality requires it. A bag that is changed too late may collapse; a bag that is changed too early wastes money. Record the pressure drop at start-up and at change-out so that the interval can be adjusted.
12. Why does the housing leak or corrode?
Leaks at the cover usually come from an old or pinched O-ring, uneven bolt torque, a damaged sealing surface or a cover that is not seated. Leaks at the flanges come from a worn gasket, misaligned piping or over-tightened bolts. Corrosion can come from a chloride level above the material’s limit, a stagnant pocket, a scratched lining or a cleaning chemical that is not compatible with the seal or the shell.
Inspect the seal groove and the cover surface for scratches or product buildup. Replace the O-ring at every bag change if the duty is hygienic, or at the first sign of hardening or swelling. For lined carbon steel, check the lining at the flange faces and the drain; a holiday in the lining will corrode the steel from the inside. For stainless, check for crevice corrosion under the bag collar and at the flange gaskets.
13. How do I change bags without contaminating the line?
Close the inlet, close the outlet, and drain the housing through the drain valve. If the process requires it, flush with clean water or a compatible cleaning solution before opening. Open the vent to break vacuum, then open the cover slowly. Remove the bag without tearing it; place it in a closed container. Clean the basket and the seal surface, inspect the O-ring, and install the new bag with clean gloves.
For hygienic duty, use a clean change-out kit, a dedicated bag container and a documented procedure. Do not change bags during a production run if the downstream line cannot be isolated. After closing, vent and leak-test before reopening the outlet. Record the bag rating, the batch number and the differential pressure. If the old bag is to be inspected, keep it intact and labeled.
14. Why is the flow uneven in a multi-bag housing?
Uneven flow in a multi-bag housing usually comes from a header that does not distribute pressure evenly, a bag plate that is partly blocked, or bags with different pressure drops. If one bag is dirtier or has a different micron rating, it will take less flow and the other bags will take more. A damaged bag plate or a missing bag can also create a short path.
Check that all bags are the same size and rating, that all collars are seated, and that the header is clean. Measure the pressure drop across each bag if the housing has individual gauges, or inspect the bags at change-out for different dirt patterns. If the header is the problem, add a flow distributor or revise the inlet arrangement. Do not balance the flow by throttling individual bags unless the housing is designed for it.
15. What spare parts and maintenance should be planned?
Keep spare bags of each rating, cover O-rings, bag collar gaskets, a basket or bag plate if the housing is critical, and a differential-pressure gauge. For lined housings, keep a repair kit for the lining and the flange faces. Store bags in a clean, dry place and protect them from sunlight and oil. Do not use a bag after its shelf life or after it has been dropped.
Inspect the housing at every bag change: basket, bag plate, seal groove, cover, drain and gauge. Check the flange bolts and the support. For hygienic duty, clean and sanitise the housing on a defined schedule, not only when the bag is changed. Record the pressure drop, the bag rating and the change-out date. A bag filter is a low-cost component, but a neglected housing can become a contamination source for the whole line.
How to use this FAQ
Use these answers to define the housing, bag and installation details before you send the RFQ. The final selection depends on flow, fluid, viscosity, solids load, micron target, housing material, seal compatibility and change-out access. For the product envelope, see the bag filter for water treatment page; for the family comparison, see water treatment filters.